Re: [akaiS1000S1100Samplers] Memory lost on S1100

2016-02-25 by belzrebuth

On 25/2/2016 2:59 \u03bc\u03bc, frankysven@... [akaiS1000S1100Samplers] wrote:
> I recently bought a S1100. It showed 16megawords on startup. I opened it and found that it actually has 4 of the 8MB boards from Mutech. Somehow only two of the boards showed up at start. I expected it was caused by oxidation, so I removed all the memory boards, checked that the dip settings where OK and reseated the RAM cards.
>
> Now only one card works, the Akais show 4 Megawords at startup. I tried rearranging the boards, reseating them, etc. Without luck. 
>
> Any idea what can be wrong?
>
> Thanks,
>
> Franky
>
>  
>  
>
I'd clean the contacts with some isopropyl alcohol and also check for
cold solder joints on the memory sockets.
You'd have to remove the mainboard though and this can be tricky.
Also physically examine that all the pin legs of the ICs on the RAM
boards are solidly attached to the PCB.
There is the possibility of dead ram boards but that's rare compared to
cold joints,dirty contacts etc