just check all contacts and cables with an ohmmeter. take your time, i'm sure it'll work! check if all chips are the right way inside, compare with pics from colins webpage. once my p3 dindn't boot full 'coz there was not enough power....... good luck! mag Robert Holmstr�m <robertholmstrom@hotmail.com> wrote: Hmmmm... just noticed that I get text... just had to turn the trim pot... What I get is the "check fail 63ED" message and the boot and flash options, but I can't get out of there. Do you think it can be the ribbon contact for the keypad? Should it answer to F1 or F3? Is there any way I can check the ribbon contacts? Thanks Robert >Hello, > >I just finished my P3 and I can't get it to boot. First time I >powered it up it did a small flash show and ended up with all lights >on the step row on. Then I remembered I had read somewhere that a >conbination of keys had to be held down the first time I power it up. >I checked the manual and tried to hold down F1 and step 7 but nothing >happened (the same sequence was played again and stopped at all >lights on). I tried again and now something happened... the lightshow >didn't start and just two leds were lit, the "tie" and "x". > >I haven't seen any text in the display yet. > >ANybody who can help me? > >THanks > >Robert > _________________________________________________________________ Hitta r�tt p� n�tet med MSN S�k http://search.msn.se/ Yahoo! Groups Links --------------------------------- Do you Yahoo!? Yahoo! Mail - Helps protect you from nasty viruses. [Non-text portions of this message have been removed]
Message
RE: [analogue-sequencer] Can't start my P3
2004-09-24 by MAG
Attachments