> and..i've noticed what i think is a bug in the 3.73 firmware; when i > try to get to the boot/flash screen by holding down func+page during > power-up, it ignores the command and continues booting... The test for FUNC+PAGE isn't in the main P3 firmware - it's in the bootloader. The bootloader code sits at the top of flash memory, and is never changed by a normal firmware update. On power-up, the bootloader code calculates a checksum for the main program, and boots it up if it checks OK. If it fails the check, or if FUNC+PAGE is held, then it presents the menu option to boot anyway, or to wait for a sysex firmware update. If it's not responding to FUNC+PAGE, that suggests that the switchboards are not connected properly, or there's a fault in the interface logic. Cheers, Colin f
Message
Re: [analogue-sequencer] Re: done! ....but...
2003-08-22 by Colin f
Attachments
- No local attachments were found for this message.