Re: [analogue-sequencer] Re: done! ....but...

2003-08-22 by Colin f

> and..i've noticed what i think is a bug in the 3.73 firmware; when i
> try to get to the boot/flash screen by holding down func+page during
> power-up, it ignores the command and continues booting...

The test for FUNC+PAGE isn't in the main P3 firmware - it's in the
bootloader. The bootloader code sits at the top of flash memory, and is
never changed by a normal firmware update.
On power-up, the bootloader code calculates a checksum for the main
program, and boots it up if it checks OK. If it fails the check, or if
FUNC+PAGE is held, then it presents the menu option to boot anyway, or to
wait for a sysex firmware update.
If it's not responding to FUNC+PAGE, that suggests that the switchboards
are not connected properly, or there's a fault in the interface logic.

Cheers,