Re: Remote control ?

2005-05-27 by em_dkj

> Nice ideas! If popular I'd suggest the Access solution over Novation -
> supplementing CCs with add poly aftertouch events rather than NRPNs.
> They're shorter.
> 
I have no experience of the Access method, but from the way you 
described it, if the Packed NRPN concept was applied straight to a CC 
rather than an NRPN, that would be shorter than the Access method as 
well wouldn't it ?

For example if CC 120 had the P3 user config options "packed" into it, 
that would be half the size of an NRPN and I assume shorter than a CC + 
poly aftertouch.

Or is my understanding of the Access method basically wrong ?

Dave