> this micron thing is more confusing that I thought. The > problem only happens when I am arp recording with the micron > in its mix mode, its single program mode is fine. When I > press a note on the micron keyboard in mix mode it is > sending the note out on the first 8 midi channels at once so > the P3 sequence immediately fills up with the same note. I > can't find any place on the micron to adjust this... of > course I want to be in mix mode so I can hear all 8 parts. I > don't understand why its only a problem in Arp record, but > is there a place on the P3 I can make sure I am only > recording one channel? This is only a problem in ARP mode because the normal record mode is only recording the most recently received note on each step, whereas the ARP mode is recording on however many steps it needs to capture every note received. It became possible to specify a single record channel in the current beta release - v3.1.006B No-one has reported any problems with the beta (they very rarely do), so give it a shot if you want to ARP with the Micron. Best regards, Colin Fraser Sequentix Music Systems Ltd http://www.sequentix.com
Message
RE: [analogue-sequencer] new P3 - ARP problem
2005-09-04 by Colin f
Attachments