Well, it was booting untill right now. All leds on upper and step mode are on but the unit doesn't boot.
Any idea?
Thanks.
----- Original Message -----
From: Colin f
To: analogue-sequencer@yahoogroups.com
Sent: Wednesday, April 12, 2006 11:24 AM
Subject: RE: [analogue-sequencer] Updating to 3.1006
> Hello, I have found some issues updating to the new SO. First
> I tried to do it with the P3 Tools 1.06 with no results, no
> data is received wit the P3. Even I tried later to receive
> patches to the utility and nothing. This application was
> working last time I used it, I checked midi channels, configs
> etc... Any idea?
That does sound like a MIDI problem at the PC end.
You could try deleting and re-defining the P3 connection in "Define P3s",
and make sure the ports are still OK.
IIRC, adding or reinstalling MIDI devices can cause them to be numbered
differently.
> My second try was with Midi OX and the P3 received data, but
> with each block I got a "Bad Data" message on the display.
> After all, rebooting the P3 shew a V 3.1006. Now it seems to
> be working and with the software updated but the "Bad Data"
> messages make me doubt. So, do you think I updated correctly
> the P3? Anybody experienced these issues?
It could be a MIDI loop causing the BAD DATA messages.
If the newly installed firmware boots up without the bootloader giving a
'CHK error', then it has installed OK.
Best regards,
Colin Fraser
Sequentix Music Systems Ltd
http://www.sequentix.com
------------------------------------------------------------------------------
YAHOO! GROUPS LINKS
a.. Visit your group "analogue-sequencer" on the web.
b.. To unsubscribe from this group, send an email to:
analogue-sequencer-unsubscribe@yahoogroups.com
c.. Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
------------------------------------------------------------------------------
[Non-text portions of this message have been removed]Message
Re: [analogue-sequencer] Updating to 3.1006
2006-04-12 by Miguel Mendoza