Yahoo Groups archive

Analogue-sequencer

Index last updated: 2026-04-28 23:15 UTC

Message

RE: [analogue-sequencer] Gate on P3

2006-05-31 by Colin f

> 1-12 gate lenght is too short. It should be 1-full. If lenght 
> set to full, note last until next note without overlap.

I see.
The way the pattern data is stored, there are only 4 bits for the length
value on each step.
So the maximum possible range is 1 to 16.
Without reducing the number of patterns, length can't be any longer.

Best regards,
Colin Fraser
Sequentix Music Systems Ltd
http://www.sequentix.com