2012-05-11 by Steven

Thanks for the reply Colin.

The Dinsync.info manual for the particular DrumDokta DRM-110 eurorack
module, the ideal trigger to achieve standard D110 sounds requires a
10ms trigger.  Having the ability to vary the length would be ideal, in
fact it would be fantastic as it would allow smearing of the output 
sound of some of these drum units.  Plus it would mean I wouldn't have
to add another module to the rack!

cheers
Steve






--- In analogue-sequencer@yahoogroups.com, "Colin f" <colin@...> wrote:
>
>
> > 1) is there an optional drum-trigger interface yet?
>
> Not yet, but it's not too far off.
>
> > 2) can you adjust the triggers?  I purchased the DrumDokta
> > and Paul reports that the ideal trigger should be 10ms triggers.
>
> On the prototype unit in my drum module, the trigger lengths are 1 or
2ms,
> hard-coded in the receiver firmware.
> Those are the two standard trigger pulse lengths used for the 808 and
909
> sounds.
> For the production board, I'll probably add support for configuration
> messages to change pulse lengths to suit different applications.
>
> Cheers,
> Colin
>



[Non-text portions of this message have been removed]