I have forwarded your bug reports about rs290 module to Bob William. Here is his answer : We have learnt that the faults are to do with power supply issues due to our modules being fitted into inferior cases from other manufacturers. It seems the +12v and +5v rails are being affected.The rs290 alone gives out 360ma and the rs95 vco's on one system being 90ma each makes 540ma before any other module is added and if the power supply only handles say 500ma then there is going to be tears. An rs15 has been ordered by one of the users so hopefully there will be no more problems. Our designer Les Newell may email the user group with detailed explanation but if you can mention that it is not a module fault(of course there may be bugs in it that will come to light in the future)then at least users or potential users will be reassured. Arnauld
Message
RS290 answer by Bob William
2003-04-23 by Arnauld Michelizza