Re: [Doepfer_a100] Re: Power ribbon cables

2005-06-05 by Bakis Sirros

hello,
if i remember well, doepfer rack case have their
connectors installed is such a way so as the red
stripe of the ribbon cables to be downwards. 
in the Analogue Solutions cabinets, the doepfer
connectors in their modules are in such a way
installed so as the red stripe to face upwards. btw,
the red stripe for doepfer and analogue SOLUTIONS
means pin1 and -12volts.
in the analogue SYSTEMS rack cases, their analogue
systems connectors have their connectors in such a way
so as their red stripe to mean 0volts.
dieter, bob, if i am wrong correct me, ok?
best regards,
bakis.





--- boward_k <bovar.kalim@eudoramail.com> wrote:

> 
> Speaking of pwer ribbon cables...
> just connected a analogue systems module to my
> analogue systems 
> RS10..which had the colored end facing
> downwords..But when connecting 
> doepfer modules to the RS10 (whoes bus connectors I
> asume are just 
> above the AS's..and by the way also apears to have 8
> bus connectors 
> instead of the told 7) the doepfers colored end
> faces upwords(arent 
> they supose to face down to??)..i dont dare to power
> up!!!
> 
> /boward
> 
> 
> 
> 


Bakis Siros
Parallel Worlds / Polariton
Athens-Greece
[Doepfer_a100] group owner
http://www.shimarecords.co.uk