You probably just blew the fuses (middle one on the left or right or both). I have blown fuses more times than I can count plugging in ASystems slightly askew, ASolutions in backwards and Doepfers with the pin on the wrong side. With modules that you have a 50% chance of getting right, it's plug, blow, reverse, works. Just get a handfull of fuses and go at it methodically, plugging in one at a time and poweing up.
Dan
plastichorneddevil <kellyborkert@hotmail.com> wrote:
having just received an RS-15 with no instructions and fewer brains, I
plugged 4 analogue solutions modules into the Doepfer slots, and
puzzled over the Analogue Systems orientation. Not thinking to look at
the ends plugged into the modules for their obvious signs, I believe I
put them in the rack power supply backwards and powered it up. No signs
of life from the RS-60 EG's, so I eventually gave up and realized the
mistake this morning. Have I done some damage?
Reversing those connectors and attempting to power it back up brought
the same results. I havent tried listening to any other modules, I
simply looked for some LED feedback, under gate or one shot conditions.
Appreciate any help!
kelly
---------------------------------
YAHOO! GROUPS LINKS
Visit your group "analogue_systems" on the web.
To unsubscribe from this group, send an email to:
analogue_systems-unsubscribe@yahoogroups.com
Your use of Yahoo! Groups is subject to the Yahoo! Terms of Service.
---------------------------------
[Non-text portions of this message have been removed]Message
Re: [analogue_systems] rack power up problems
2005-11-13 by Daniel Levey
Attachments
- No local attachments were found for this message.