Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

Re: Editor for BControl Nano?

2009-02-19 by bernard.escaillas

I know the BCN can receive a sysex message of type 'dump'.

I was speaking of an undocumented message of type 'Request' to ask 
the bcn to send a dump. Most midi device have that (except my 
Novation Drum Station :( ).

Anyway, i have just uploaded a pdf document ( in files / documents ) 
with my first exploration of the BCN sysex implementation.

There are several points not solved yet :
- the request messages that would trigger the BCN to send a dump
- the param messages that would allow to change a single item of patch
- the values appearing here and there in the dump that have no logic 
and not tied to any know parameter. Either it is only uninitialized 
memory area with random value (booo, bad programming pratice) or 
there are some undocumented parameters set only in the factory. Don't 
ask why but i feel it is the first solution...

In case i have sent a mail to Behringer tech support. They might as 
well find the orignal BCN specification with the MIDI implemention... 
let's cross fingers.