Bc2000 (for the BCF2000 & BCR2000) group photo

Yahoo Groups archive

Bc2000 (for the BCF2000 & BCR2000)

Index last updated: 2026-04-28 23:16 UTC

Message

Bcn44 with 2 variables

2009-03-10 by philk22002

Hello
is it possible to send 2 variables of 4 bits with the Bcn44 ?

the message with Bcr2000 for mys Kenton Pro solo MKII
".tx $F0 $00 $20 $13 $03 $20 14 1 val0.3 val4.7 $F7 "


and structure of the sysex message to kenton

  "The Pro-SOLO mkII can be controlled by Sysex messages in the following
format:
The first five bytes of sysex for the Pro-SOLO mkII are always the same
for all data types
[ 1] 0F0h - Sysex command
[ 2] 00h - Company ident first byte
[ 3] 20h - Company ident second byte
[ 4] 13h - Company ident third byte
[ 5] 03h - Product code – Pro-SOLO
[ 6 ] 0dddnnnn - where ddd is the data type and nnnn is the device number
where ddd = 010 = data change (so for device #1, this byte = 20h)
[ 7] 0000uuuu - where uuuu = low 4 bits of parameter address
[ 8] 0000hhhh - where hhhh = high 4 bits of parameter address
[ 9] 0000uuuu - where uuuu = low 4 bits of data
[ 10 ] 0000hhhh - where hhhh = high 4 bits of data
[ 11 ] 0F7h - end of exclusive ) "

thank you

Philk

Attachments

Move to quarantaine

This moves the raw source file on disk only. The archive index is not changed automatically, so you still need to run a manual refresh afterward.