Re: BCR2000 Encoders

2010-01-07 by nicobcr

Hi Royce, thanks for your reply!.

You mean that ¨.resolution 96 96 96 96¨ would be the cause of the problem or I got it wrong?.
Actually, I have recently instaled a preset which emulates a mackie control on ableton live (I'm sure you know it, donwloaded from inet). Can't check right know bacause I'm not at home but I think resolution is set just like you mention here. The weird thing is that all enconders on top row are all equaly configured.
You mean that ¨.resolution 96 96 96 96¨ would be the cause of the problem or I got it wrong?
  
Anyway, if I rotate the encoder applying some force perpendicular to its shaft, it will work correctly. So, logic indicates it's a mechanical issue.

Thanks and regards!,
nicolas.

--- In bc2000@yahoogroups.com, "rpcfender" <rpcfender@...> wrote:
>
> Hi Nicolas
> 
> you can program the encoders in such a way that this problem would manifest itself.
> 
> Try programming one of the encoders like this 
> 
> $rev R1
> $encoder 1
>  .showvalue on
>  .mode 1dot
>  .minmax 0 127
>  .default 0
>  .resolution 96 96 96 96  ; this is the problem line
>  .tx $B0 7 val
> $end
> 
> This is a volume control on channel 1
> 
> Use MidiOx to check the output
> 
> Good luck
> 
> Royce
> 
> --- In bc2000@yahoogroups.com, Nico Bcr <nicobcr@> wrote:
> >
> > Hello everybody!
> > I'm new in this group and this is my first post (but it won't be the last).
> > This time I need some help of you:
> > 
> > I have found that three of the push-encoders in the top row are damaged. They work normal if I rotate them slowly but they don't change values if I rotate them relatively fast. I have not tested all other encoders already (don't use the unit often) but possibly there are more encoders damagaded. 
> > 
> > My question is: does anyone knows the encoders specifications/part number???. Would like to buy them off-the-shelf if possible.
> > 
> > BTW, I opened the unit last night and cleaned one of the affected encoders with contact cleaner but I didn't have the time to reassemble the unit and try it yet. Anyway...it won't work....I feel it's another mechanical issue.
> > 
> > Waiting for some feedback from you!
> > 
> > Best regards!
> > 
> > Nicolas.
> >
>