Re: getting channel meters to work with BCR2000 in Mackie mode

2011-09-04 by -

Yes do tell. 
Do you still have use of that knob, or is it just for meters?
I would love to get that working. 

--- In bc2000@yahoogroups.com, "OlliK" <NoUse@...> wrote:
>
> I got it working.
> The Mackie protocoll is sending the level meters info as channel pressure (aftertouch).
> Since it's all sent on Midi channel one I remapped the aftertouch data to different Midi channels with MidiOx.
> I now have 8 encoders working as level meters when I use the BCR in Mackie mode. Works nicely.
> 
> If anyones interested I can describe the detailed steps how to do it.
> 
> 
> --- In bc2000@yahoogroups.com, "OlliK" <NoUse@> wrote:
> >
> > Anyone using the BCR2000 as Mackie emulation with a DAW and tried to get the LED's as level meters to work ?
> > 
> > I've found this post regarding the implementation:
> > 
> > http://forum.jazzmutant.com/viewtopic.php?p=4637&sid=66e85679b9dc0739f3412d83a8cbfffc
> > 
> > [qote]
> > It's ChannelPressure (D0) followed by 8 bits.
> > First 4 bits are channel , second 4 bits are level
> > So for example , Channel 1 sends a value of 0-16 ( 10 actually) to indicate level in the channel
> > Channel 2 sends 17-32 etc. These are all transmitted on MIDI channel 1
> > [/quote]
> > 
> > Here's another similar post:
> > 
> > http://www.cycling74.com/forums/topic.php?id=12175
> > 
> > I somehow get it to work when I set one encoder to aftertouch with BC manager, the LED's are indeed flickering when sound is played.
> > 
> > But I lack the understanding of detailed Midi stuff, so I could get one encoder for each of the eight MCU channels.
> > Is that even possible ?
> > Anyone tried this ?
> > 
> > Thank you.
> >
>