--- In bc2000@yahoogroups.com, dave watkinson <dave422x@...> wrote: > I reconnected the BCR to my MIDI interface and put it into S3 mode. BC Manager can't detect it. In mode S-3 anything received at the BCR's MIDI IN is directly routed to the BCR's MIDI OUT A. So in S-3 you shouldn't use MIDI OUT A in a bidirectional setup with your computer; instead, you should use MIDI OUT B. Alternatively, use MIDI OUT A under S-4. (MIDI IN is routed to MIDI OUT B in this case.) > Despite the lack of BCR detection (I disabled all my other USB / MIDI devices) I tried to open the Behringer default sysex file in BC Manager, and was greeted by this message: > Error: MIDI system exclusive error > Wrong command > Send Memory ($34) > This may be the result of a feedback loop > Message 1 This is in line with what I wrote above: in S-3, BC Manager gets any message it sends to the BCR's MIDI IN straight back from MIDI OUT A. Incidentally, the "Send Memory ($34)" messages contain BCR firmware data: if the BCR shows "1.10" upon power-up, there is no need whatsoever to try to update its firmware. (In fact, it's a bit dangerous.) Hope this helps, Mark.