Bump.
I am currently facing a similar, perhaps identical issue.
First post, btw:
I bought the bcr2000 couple days ago. I've tried dumping ableton's automap and using bcmanager and midiox to load presets for my alpha juno (all of which I've gotten from the files in this group) to no avail. I am running windows 7 64-bit.
Ableton behavior: blinking lights and Er22
BCmanager behavior: blinking lights, begins load status and stops immediately in the middle; if I send a sysx line by line Er22 comes up.
MidiOX behavior: seems to load successfully on the midiox software but nothing useful happens on the bcr
Has anyone resolved this problem? It is extremely frustrating. Any help at all would be tremendous.
Michael
---In bc2000@yahoogroups.com, <uwejuelich@...> wrote:
I tested with xp, all works fine. In win 7 64bit - no chance. If anyone had similar problems and solved this, please help ;-)
thx
Von:
bc2000@yahoogroups.com [mailto:
bc2000@yahoogroups.com ] Im Auftrag von Mark v.d. Berg
Gesendet: Samstag, 1. Dezember
2012 09:52
An: bc2000@yahoogroups.com
Betreff: [bc2000] Re: Err6 and
Err22
--- In bc2000@yahoogroups.com,
Uwe Jülich <uwejuelich@...> wrote:
> Thanks for you advice. In Windows XP all works as expected, I got thisMode U-1 almost rules out message duplication via weird signal paths.
> problems since Windows 7 64bit. Operation Mode is U-1. I'll test the unit
> again with XP tomorrow, so I can check it's ok.
So more likely it's a problem related to the Windows 7 USB driver for the BCR (i.e. Behringer's 1.0.10 - I'm not sure about Microsoft's generic "USB Audio Device"):
In my experience this driver sometimes inserts a weird character in its MIDI I/O device names - although I'm not sure if this could cause "your" errors 6 and 22.
In any case, in BC Manager you should first make sure that the BCR's devices are checkmarked in the Options->"MIDI devices" dialog box.
Hope this helps,
Mark.