Re: Electrolytic V value and CGS06 output querry

2004-10-24 by bbluthang

hi
> On the pcb of Burst Gen there is a pad CLK O is that a clock
output?

the Clk O connects to the 'switch' on the clock-in jack.
if nothing is plugged into this jack, you can set the burst gen up
with the speed pot and range switch. once you plug in, this part of
the circuit is disconnected.


> I'm
> shopping for parts and wonder if I could replace the VOLT value of
> electrolytic caps by any other value as long as it is higher than
> the PSU used puts out: Can I use 47uF 16V instead of 47uF 25 V (for
> the Burst Gen.)?

if running 15v, i'd feel uncomfortable using a 16v electro for
decoupling. it is okay to go bigger than 25V. 10uF 35V or 50V would
be fine.

hope it all goes well
cheers
andrew