Thank you this is extremely usefull stuff. Can't wait for the .pdf file now. :) > -----Original Message----- > From: bkuris [mailto:benjamin.kuris@...] > Sent: Wednesday, August 04, 2004 6:05 AM > To: chromapolaris@yahoogroups.com > Subject: [chromapolaris] Diagnostics > > > This is going to be fairly long-- I'll try to make a .pdf of the > actual manual soon. For now I'll abbreviate: > > Diagnostic readouts: > Lower Function - D - 1: displays charge on battery in right column > of LEDs in assignable control section. Expect 4-5. Replace cells if > less then 2 LEDs light. If 7 LEDs light, the battery cap. is > overcharged which is usually an open between cell terminal and cap. > > L F - D - 2: flashes number led of revision of SW > > L F - D - 3: Turns on all LEDs to check LEDs and digital power > supply for max current. > > L F - D - 4: (for bryon!) turns on LED above master slider when > master slider is positions to produce a value of 255. This checks > out the range of the A/D convertor > > L F - D - 12: erases all memory. don't do this! > > L F - D - 10: MIDI reset > > L F - D - 11: warm reset. For minor glitches like stuck notes > > L F - D - 12: cold reset. like toggling the power switch > > *adjustments and checkout* > Digital level: turn on all LEDs. measure at P3 pin 3 and pin2 adjust > R9 for +5V (10mv tolerance) > > Reference level: p4 pin 1 and p6. adjus r5 for +5V within 10mV. > > DC ok threshold: back off R17 to minimum (full CCW) then turn > clockwise till LED CR10 lights. Later models have a different design > w/no adjustments > > ADC range (for slider!): push master slider up to max and pull all > other sliders to minimum. Press lower function D-4 and watchi the > LED in the master secetio nof the panel (volume/tune). Turn R45 > clockwise to maximum, then back off couterclockwise until LED > lights. Continue turning CCW 5 degress beyond this point. Press > lowre Function to return panel to normal operation. > > DAC null: using 3.5 or 4 digit DMM to measure between TP1 and TP2 > adjust R46 until the meter reads within 100uV of 0 (-.0001 to > +.0001V). This is a critical adjustment and quite sensitive. > > lever position: measure the DC voltage between the center terminal > and ground of each pot in the lever assembly. At rest should be 2- > 3V. IF either is out of range use 1/2 inch wrench to loosen the nut > on the pot, rotate the pot until the voltage reads 2.5V and retighten. > > skipping so stuff... > > Lever range: > LF - A - 7 and move levers (pb/mod) through the entire mechanical > range. The computer will adjust to the measured range. > > Pedal range: > LF - A - 8 as above but move pedal > > volume offset: to long to type > > key sensitivity: LF - A -10. Use a touch sensitive patch. If a key > feels over or under senstive, press a key and use master slider to > adjust sensitivity. > > final stuff for Bryon to debug ADC: > check out ADC voltage (R45 adjustment above). > Output of sliders are selected for ADC by MUX Z5 (on control panel). > 1/2 of Z54 buffers the mux output which is fed into Z53 (ADC0804 ADC) > the othe r1/2 of Z54 buffers the ADC reference voltage (R45). > Make sure all these chips are well seated. > > You can also use MIDI controls if all else fails or to verify that it > isn't a voice problem... but that will have to wait (I guess you > could check the range of the midi out signals using a PC and a midi > monitor program). > > Good luck, > Ben > > > > > > > ------------------------ Yahoo! Groups Sponsor > --------------------~--> > Over 1 billion served! The most music videos on the web. > Click to Watch now! > http://us.click.yahoo.com/Xkrq7C/IARHAA/n1hLAA/QnLolB/TM > -------------------------------------------------------------- > ------~-> > > > Yahoo! Groups Links > > > > >
Message
RE: [chromapolaris] Diagnostics
2004-08-04 by fuse
Attachments
- No local attachments were found for this message.