NEC Multisynch LCD2690WUXi

2007-08-31 by Rollin

I recently posted an item on the DPReview Forums asking about 
people's experience with the subject NEC monitor.  One question delt 
with the use of the Spyder2 colorimeter to profile the monitor.  
Below is the response that I received from a person associated with 
NEC.

David Tobie (or anyone else), any comments?

Rollin

---------------------------
> First, I already own the Colorvision Spyder2 Pro package so am 
> looking at the BD version (basic) rather than the SV one that has 
> the Spectavision II software and the colorimeter puck. I have 
> managed to verify that I can purchase the Spectravision II software 
> separately > from NEC for $170 U.S. The specs for the version II of 
> the Spectravison indicate it does work with the Spyder2 puck. 

While the Spyder2 is supported by the SpectraView software, it is not 
actually recommended to use this device on the LCD2690 because of 
measurement errors due to the wide color gamut of this display. The 
preferred measurement device is the X-Rite iOne Display v2. 

-- 
Will Hollingworth 
Manager of OEM Product Design & Development Engineering 
NEC Display Solutions of America, Inc.