I recently posted an item on the DPReview Forums asking about people's experience with the subject NEC monitor. One question delt with the use of the Spyder2 colorimeter to profile the monitor. Below is the response that I received from a person associated with NEC. David Tobie (or anyone else), any comments? Rollin --------------------------- > First, I already own the Colorvision Spyder2 Pro package so am > looking at the BD version (basic) rather than the SV one that has > the Spectavision II software and the colorimeter puck. I have > managed to verify that I can purchase the Spectravision II software > separately > from NEC for $170 U.S. The specs for the version II of > the Spectravison indicate it does work with the Spyder2 puck. While the Spyder2 is supported by the SpectraView software, it is not actually recommended to use this device on the LCD2690 because of measurement errors due to the wide color gamut of this display. The preferred measurement device is the X-Rite iOne Display v2. -- Will Hollingworth Manager of OEM Product Design & Development Engineering NEC Display Solutions of America, Inc.