Yahoo Groups archive

Datacolor User to User Support Group.

Index last updated: 2026-04-28 23:18 UTC

Message

Re: Help calibrating with Spyder3 Elite

2009-05-13 by tech4x5

Thanks for the reply.  You have always been extremely responsive and helpful.  My OS is Windows XP Home and I am using PS CS4.  I am using a Dell UltraSharp 2407 FPW-HC monitor and have been using it for over a year.  And my calibrations worked in the past with Spyder2 PRO on it.  It is the same display, but I have moved so my viewing area is obviously different.  The viewing environmemt seems visually to me to be about the same, but obviously it's not exact.  Spyder2 PRO revealed both my old and current viewing areas to be be moderately low and recommended 5800 and 125 cd/m2. 
     When you ask for profiles, do you mean the .icm profiles?  If so, I can send you a prior Spyder2 and a current Spyder3 Elite profile.  Please tell me how to get this to you.
     When using Spyder2 PRO previously, I ended up calibrating after first adjusting my Br control to get CIExxY value to be about 125-130.  When using Spyder3 Elite, I am just running it at the factory default settings with the brightness at 50%.  Could this make have anything to do with my problem?
     Just let me know how to get the profiles to you and I'll send them right away.  

Thanks,
Matthew Kraus



 --- In colorvision_group@yahoogroups.com, C D Tobie <CDTobie@...> wrote:
>
> 
> On May 12, 2009, at 9:34 PM, tech4x5 wrote:
> 
> > I am having difficulty calibrating with Spyder3 Elite.  I had  
> > previously used Spyder2PRO with good results before purchasing  
> > Spyder3 Elite.  Whenever I calibrate now, my monitor is flat, not  
> > vibrant, dull, pale.  My soft proofing to my photos which I print  
> > with profiles I make from PrintFix Pro is also off.  It is not my  
> > prints, they are fine.  I just can't get my monitor to calibrate well.
> >
> > When I go through the new display process using Spyder3 Elite, I  
> > think where I am getting into trouble is with the backlight control  
> > and the white luminance. I check the backlight control button  
> > because the brightness control on my monitor controls the backlight.  
> > When I reset to factory default, brightness goes to 50%. If I  
> > calibrate at this level, the monitor is much too bright and CIExyY  
> > measures about 250. When I check the ambient light recommendations,  
> > it suggests 5800 and 125. 125-130 has always been the white  
> > luminance value I have used in the past when I calibrated with  
> > Spyder2 and my monitor always looked good at this setting. It was  
> > recommended to use Colorimeter CIExyY to see my white luminance  
> > value and so I have in the past tried to adjust the brightness  
> > control to get a CIExyY value of about 125-130 when I calibrated.  
> > This way always worked well for me in the past with Spyder2.  When I  
> > do that now with Spyder3, my monitor is still pale, flat, not  
> > looking as I am used to it looking. So the problem is, do I leave  
> > the brightness at factory default, which really looks bad, or do I  
> > adjust my brightness control, and if so, to what level?
> 
> What OS, and what application and app version are you viewing photos  
> in? Have you just changed displays, or do you have profiles from the  
> same display from both S2Pro and S3Elite? If so, lease email both to  
> me off list in a zip archive. What display make and model? What color  
> gamut does it claim, if it claims one?
> 
> C. David Tobie
> Global Product Technology Manager
> Digital Imaging & Home Theater
> CDTobie@...
> 
> 
> 
> Datacolor
> www.datacolor.com/Spyder3
>