Re: Display turns green during calibration

2009-05-28 by Doug Kerr

Hi, e,

--- In colorvision_group@yahoogroups.com, "ejc_1@..." <ejc_1@...> wrote:
>
> Using a Spyder 3 pro, my screen turns to a green tint during the gray balance.
> 
> Any ideas/

Well, I suspect that until the calibration process is finished (including the "gray balance" phase of it), the final LUT load that will make sure the display actually displays gray for a gray input hasn't been finished and implanted, so the "gray" displayed may in fact not be gray - it's what the display at this point in its life (not yet calibrated) displays for a "gray" input.

The question is, after calibration is finished, does the display put up "gray" for a gray input?

Unfortunately, in the Pro version, we can't ask the calibrated system to put up what should be gray and see if it looks gray (and measures gray). 

Best regards,

Doug