--- In colorvision_group@yahoogroups.com, CDTobie@... wrote: > > > In a message dated 4/16/06 7:03:40 AM, hanson102@... writes: > > > > since i was using a preset of 6500K of the monitor, i had to swtich to > > manual adjustment to achieve this. however, my problem is, my RED > > slider is already maxed out (it is the column with the lowest value), > > my BLUE slider (2nd highest column), i can easily bring down. worse, > > my GREEN slider is fixed by the monitor and i cannot adjust at all > > (which is the column with the highest value). > > > > questions: > > 1. does this mean that my monitor is incompatible? > > > > If your red is too low, and can't be raised, while your green if fixed, then > you can't adjust your gains manually. Choose the preset, and let the software > fix it from there. but my problem is that the spyder2PRO gives me profile that has a reddish cast. ... doesn't this mean that the profile has an error or something? it should give me a good 'white' temperature but it's just too warm. what is the important of achieving a 0.5 difference on the color temperature? > > C. David Tobie > Product Technology Manager > ColorVision Business Division > DataColor Inc. > CDTobie@... > www.colorvision.com >
Message
Re: Spyder2Pro on a Viewsonic CRT Monitor
2006-04-16 by hanson102
Attachments