Re: [elektron] SID Station SysEx Direct Program query :-/

2005-10-12 by David Davis

Yes, I tried leaving that byte to 00 as well, 
it didn't make any difference!




--- In elektron-users@yahoogroups.com, Corey Appleby
<digitalwank@m...> wrote:
>
> 
> That should work just fine.  Have you tried it leaving the 00 as just  
> 00?  I have a little sid editor I was writing for Linux and looking  
> at my code I always left that set to 00 even though my Sid was on  
> various channels while I was writing it, and it always worked.
> 
> c.
> 
> On Oct 11, 2005, at 5:33 PM, David Davis wrote:
> 
> > Here, I am trying to use my Kenton Control freak to tweak
> > my SIDStation's filter resonance.
> >
> > Using a diagnostic program on my PC, I am sure I am sending it
> > this hex string:
> >
> > F0 00 20 3C 01 (00) 04 00 18 0F 04 xx F7
> >
> > (where xx is a single hex byte from 00 to 0F,
> > ie 0 to 15 decimal)
> >
> > Also the (00) is brackets,
> > i tried changing this to 06Hex,
> > cos page 39 of the Owners Manual say it is the "base channel",
> > and my base channel is 7.
> >
> >
> > But these messages do nothing :(
> > ANy ideas what I'm doing wrong?