Re: [elektron] Re: SQ16 resets the sidstaion when I start it!

2000-07-17 by Daniel Hansson

Thanks for testing and sending the results!

On Mon, 17 Jul 2000, Shawn Mativetsky wrote:

> It's also sending SPP.  I'd say that this might be the problem, but the
> SidStation resets before the end of the sequence (where the SPP appears)
> ... it does not play any notes.
> 
> Have a look:
> 
>  TIMESTAMP PORT STATUS DATA1 DATA2 CHAN NOTE EVENT
>  0003472E    2     9D    00    00   14  C 0  Note Off
>  0003472F    2     9D    1C    50   14  E 1  Note On
>  0003476D    2     8D    00    00   14  C 0  Note Off
>  0003476E    2     8D    1C    64   14  E 1  Note Off
>  00034F26    2     F2    00    00   --   --  Song Position Ptr
>  00034F26    2     F2    10    00   --   --  Song Position Ptr
>  00034F27    2     8D    00    00   14  C 0  Note Off
>  00034F28    2     8D    1C    51   14  E 1  Note Off
>  00034F2A    2     8E    2E    51   15  Bb2  Note Off
>  00034F2B    2     82    2C    51    3  G#2  Note Off
> 
> (also weird that it's sending note offs for channels 15 and 3, because
> those channels are muted on the sequencer)

That shouldn't be any problems for the SidStation. It also shouldn't be a
problem with the Song position pointer from the information I've got here,
as it is not specific for any channel - and muting the SidStation-channel
makes it stop resetting.

Now, could you try sending the data you received from the SQ16 from the
computer to the SidStation? This way we'll see if it's an electrical
adaption problem or a problem with the actual data sent.

 //Daniel