Hi Jammie, Thanks for the suggestion, however I think the PSU is fine. I read 5.04v on yellow, 12.3v on orange and -11.89v on violet coming off the PSU harness at the CPU PCB. -Dave > On Feb 17, 2014, at 8:30, "jammie" <jammie.emma@...> wrote: > > > > sounds like you have lost the 5v connection > > the lcd uses 5v the cf card reader uses 5v and the floppy uses 5v > > i would check the 5v rail on the psu > ----- Original Message ----- > From: David Sotnick > To: emax@yahoogroups.com > Sent: Monday, February 17, 2014 4:25 PM > Subject: [emax] Diagnosing non-functional Emax > > > Hi all, > > Now it's my turn… I'm sad to report that my beloved Emax SE Rack which I upgraded to SCSI and slim floppy is no longer booting. > > Symptoms are: PSU voltages look good at the drive power connector. All LEDs on the front panel come on at power-on except load and enter. No LCD display and no floppy or CF reader activity. :-( > > I have re-seated all cables but have not yet removed and re-seated any socketed ICs. It has just been sitting in a rack, so nothing has been jostled. > > Any suggestions on where to start? > > -Dave > > p.s. even more frustrating: I missed out on a $60 working Emax SE on a local Craig's list ad which posted the day before I discovered my Emax was dead. :-( > > No virus found in this message. > Checked by AVG - www.avg.com > Version: 2014.0.4335 / Virus Database: 3705/7098 - Release Date: 02/16/14 > >
Message
Re: [emax] Diagnosing non-functional Emax
2014-02-17 by David Sotnick
Attachments
- No local attachments were found for this message.