i bet you used lead free solder
----- Original Message -----
From: David Sotnick
To: emax@yahoogroups.com
Sent: Tuesday, February 18, 2014 4:49 AM
Subject: [emax] Re: Diagnosing non-functional Emax
Well I opened up the Emax again, all PSU voltages were good at the floppy and inverter.
Taking a scientific approach, I went over all the mods I made, pin by pin and found some cold solder joints on the new OLED display I installed.
Fixed those and she's back!!!
*phew*
-Dave
> On Feb 17, 2014, at 8:25, David Sotnick <sotnickd@...> wrote:
>
> Hi all,
>
> Now it's my turn… I'm sad to report that my beloved Emax SE Rack which I upgraded to SCSI and slim floppy is no longer booting.
>
> Symptoms are: PSU voltages look good at the drive power connector. All LEDs on the front panel come on at power-on except load and enter. No LCD display and no floppy or CF reader activity. :-(
>
> I have re-seated all cables but have not yet removed and re-seated any socketed ICs. It has just been sitting in a rack, so nothing has been jostled.
>
> Any suggestions on where to start?
>
> -Dave
>
> p.s. even more frustrating: I missed out on a $60 working Emax SE on a local Craig's list ad which posted the day before I discovered my Emax was dead. :-(
No virus found in this message.
Checked by AVG - www.avg.com
Version: 2014.0.4335 / Virus Database: 3705/7103 - Release Date: 02/18/14Message
Re: [emax] Re: Diagnosing non-functional Emax
2014-02-18 by jammie
Attachments
- No local attachments were found for this message.