Re: [emax] Re: Why does my Emax II sample in mono ?

2009-10-22 by tu@...

Check the output board, if you have a 5326 ADC then you have stereo sampling hardware. If it has a 5126 ADC then you have mono sampling. 

If you have a 5326 ADC and still cannot access stereo sampling then either the stereo sampling upgrade is not installed properly or the EEPROM 
has "forgotten" you have stereo sampling capabilities...

/Tristan

Thursday, October 22, 2009, 5:34:19 PM, you wrote:

>
  
It sounds strange to me. I have a 2212 keybooard (2mb) and it samples in Stereo Mode.

Go to Sample module, and check if the LCD shows "CALIBRATING ADC". It is said the emaxII can sample in stereo if you get that message.

Try to read the revision board for the main PCB for checking with other users, maybe it has got to do with it. 

Next time I open mine I will check the board rev and so.

--- In emax@yahoogroups.com, "yojx" <rapman@...> wrote:
>
> Hello,
> 
> My Emax II is a 2213 2MB Rack model (I have checked it in the back of the sampler) and I use the OS version 2.10.
> 
> So, it supposes to allow sampling in stereo but it does not. For instance, when I navigate to Sample > Place Sample, the choices are Pri/Sec but no 
Ster option.
> 
> Do you have any idea ? Do you think it is an OS issue ?
> 
> Thanks
>