ok. so i have TWO emax II's that behave the same. things like on-off termination has been tested. the Plextor behaves just like the apple cd300plus cd rom which is not supposed to work anyway. both emax ii's have internal disk: one has an apple scsi hd, the other has a syquest. now if i attached syquest external drives to either of these, everything works perfect. as soon as add a cdrom drive either alone or before or after the external syquest, the system wont boot ! the cables i used with the cd rom works with the syquest. i am going to repeat all the test tomorrow, but if you had better ideas, please let me know. this is really odd! adam --- In emax@yahoogroups.com, "esynthesist" <esynthesist@...> wrote: > > Adam, > > I honestly think your Emax-II has a problem. > - You have tested the Teac CDROM (mentioned on this site) and it didn't workon your Emax-II... while it works perfectly on my Emax-II as you know. > - Now you have tested the Plextor and it doesn't work neither... while this one also works perfectly on my Emax-II. I have just tested it on each of my four Emax-II samplers and it worked well on all of them. > The jumpers are set as follows: > 1 - on (prty) > 2 - on (term) > 3 - off > 4 - on (block) > 5 - off (?) > The drive is a November 2000 edition in external case. > > > --- In emax@...m, "Adam" <fake@> wrote: > > > > The site says it is compatible with the EMAX II. Who said this? Just bought one from Ebay for quite some money and it does NOT appear to be compatible. > > > > I'd appreciate the comments of one who had success with this one. > > > > thanks! > > >
Message
Re: Plextor PX-W124TSe (Plexwriter 12/4/32)
2011-10-26 by Adam
Attachments
- No local attachments were found for this message.