just put the 2 spades together and tape
they are not needed as the emax2 psu version was switchmode and auto sensing circuits for 110vac and 220-240vac
where as the emax version 1 psu had a switching transformer that could put the 110 dual inputs into series to make a 240 circuit via the switch on the back thats what the 2 red wires are for
they arnt needed and dont have any electrical connection on the new psu
----- Original Message -----
From: llingo_apt
To: emax@yahoogroups.com
Sent: Wednesday, June 13, 2012 11:09 PM
Subject: [emax] replacing power supply with one purchased from epr
I cannot find a spot to hook up the voltage selector wires on this new power supply i just purchased from eps...everything is hooked up otherwise in their proper spot but these two wire locations seem to have no home!?
any help would be greatly appreciated
thanks
[Non-text portions of this message have been removed]Message
Re: [emax] replacing power supply with one purchased from epr
2012-06-13 by jammie
Attachments
- No local attachments were found for this message.