Yahoo Groups archive

Emax

Index last updated: 2026-04-28 23:23 UTC

Message

Re: [emax] replacing power supply with one purchased from epr

2012-06-13 by jammie

just put the 2 spades together and tape 

they are not needed as the emax2 psu version was switchmode and auto sensing circuits for 110vac and 220-240vac

where as the emax version 1 psu had a switching transformer that could put the 110 dual inputs into series to make a 240 circuit via the switch on the back thats what the 2 red wires are for

they arnt needed and dont have any electrical connection on the new psu
  ----- Original Message ----- 
  From: llingo_apt 
  To: emax@yahoogroups.com 
  Sent: Wednesday, June 13, 2012 11:09 PM
  Subject: [emax] replacing power supply with one purchased from epr


    
  I cannot find a spot to hook up the voltage selector wires on this new power supply i just purchased from eps...everything is hooked up otherwise in their proper spot but these two wire locations seem to have no home!?

  any help would be greatly appreciated

  thanks



  

[Non-text portions of this message have been removed]