Re: Emax II failing to boot from SCSI device

2012-12-18 by dwv1957

You cannot use ID7, 7 is the address of the scsi controller, set it to something between 1 and 6 and it should be fine (0 is the floppy)

Dave


--- In emax@yahoogroups.com, Francis Cote  wrote:
 
 I have the same annoying issue. Is this EEPROM replaceable?
  On 2012-12-18 12:10 PM, "Simon"  wrote:
 
  **
 
 
  Hi Guys.. I posted this up a while ago, but am looking for a solution here
 
  The Emax boots from floppy, but when I try to assign it to boot from an
  internal SCSI drive (ID7) it says it saves the setting but still searches
  for the floppy on bootup.
 
  The settings appear to be saved as it is still set to ID 7 when you go
  back into boot ID settings but the Emax still insists on a floppy being
  inserted to boot
  The Emax should be able to boot from any ID right?..
 
  Is this likely a failing of the EEPROM at IC24?..
 
   
 
 
 