Hi! My website isn't online, yet.... a lot of work and litte time... sorry.. have patience... About the valve- distortion... it's no problem for me to repair it... but via email it's difficult to explain how to fix the problem... do you know which hardware-version you've got?... you should first check the heating- voltage (Vh = 12,6 V DC on pin 4 and 5 of the valves) (or look at the valves... does the heaters glow red???).... and than... the plate - voltage (+B = approx. 350 V on C252).... and than...you said no output , if you switch to ANY(!) valve distortion (clean, dist, sat. tube), right.... then check the signal on pin 1 of U6 (this is the output of the OP which goes directly to pin 2 of V1 ... it's the input signal to the valve- section)..... tell me the results and we can go further. D. ----- Original Message ----- From: "Chris Geske" <geskec@...> To: "Dieter Waechter" <waechter.dieter@...>; "Reg" <reg@...>; "GSPGroup1" <gsp-2101@yahoogroups.com>; "GSPGroup2b" <2101@...-dod.com>; "GSPGroup3" <GSP2101@yahoogroups.com> Sent: Monday, December 03, 2001 5:53 PM Subject: RE: 2101: Schematics for GSP 2101 > Dieter: > > Couple questions for you: > > 1.) Where is your website? > > 2.) I have a 2101 that has no output when using a tube distortion. I've > switched the tubes with no resolve. Any ideas. The solid state distortion > works fine, but whenever I turn on the tubes, nothing at the output. > > Chris Geske > LIMS Manager > Northern Lake Service, Inc. > email: lims@... > phone: 715-478-2777 >
Message
Re: 2101: Schematics for GSP 2101
2001-12-04 by Dieter Waechter
Attachments
- No local attachments were found for this message.