--- In gsp-2101@yahoogroups.com, "Mike" <mswift1974@...> wrote: > > My 2101 stopped working. Removing the cover revealed a white wire > leading from the front input jack, but not connected to anything I am > sure this is the culprit. Could someone take a decent digital > photogrph of the inside of there 2101 for me? > > Thanks! > here is a diagnosis I received from Dieter after viewing the images: There are more than 2 problems in your unit! 1. The white wire must be mounted on the left small PCB where the power switch is soldered. There was a lug, at position QT1. It is broken away. So solder the wire to the solder via "QT1". 2. The transformer is loose. fasten it with a screw and a nut! 3. Resistor R522 is blown! its a 10 ohms 1/4 watt carbon film. If you would replace it, it will probably blow again. Before you replace it you'll need to remove the defective part in the +-12V circurity. It can be many parts so you have to measure.