> Is there anything you should learn from ? ;-) Some of the capacitors here and there were almost dead so we had to be replaced them all. > Did you replace them with the same type? Yes, the technician replaced them one by one with the same type/size new capacitors. Also, as the most of the ICs are socketed, we also replaced them one by one with new same type ICs and the issue remained the same. > In general recapping in 30 years old synths is not required beside > a few exceptions: 1.) Tantalum capacitors. 2.) Caps in the power > supply, if they are close to the regulators heat sinks. > Recapping of the audiopath makes sense in large professional mixing > consoles, which ran continously for 30 years 24/7 without beeing > switched off. In these consoles the continuous heat inside the > console can dry out the capacitors. But a synth usually never > "lives" under such > conditions. I agree, I have only replaced the capacitors on power supplies, of my old synths, but in this case we had to replace them all. What do you suggest to check ?