Hi Laszlo, Thank you for your message. I have already forwarded your steps to the Technician. He will probably check them during next week and I will let you know the results of course. --- In korg_mono-poly@yahoogroups.com, Laszlo Kovari <friendomatic@...> wrote: > > 1. Set osc volumes to min and check the noise issue with open filter and > vca. This way you can detect whether problem relates to vcf+vca or > oscillators. > 2. Check board to board connectors. A loose connector situation can cause > instability. > 3. Probably the DAC makes the noise, "pacman" like sound -> instabile CV to > oscillators. Check if all 4 oscillators involved in the issue or just one. > 4. Maybe a bad cap-polarity? Double check your recapping work. > 5. Recapping makes sense in my opinion. I recapped the power supply and the > vcf+vca board in my MP. Electrolytic capacitors have a 2000-3000 hour > lifetime before they go out of specification. Out of spec means they do > their jobs less and less effectively, sound becomes degraded and noisy over > years. > > Laszlo >