Re: Filter Resonance Not Working

2015-12-03 by voltagegrove@yahoo.com

so far I have been able to reseat the 2044, which did not have any effect. I have also tested the R2 resistor which is fine, although it seems to be a 4.7k instead of a 1.7k... I have also tested continuity between the Res pot, trimmer, resistor and 2044; which there is a full connection. I have ordered a new 2044, should be here early next week. I am just going to start there.

My next task will be to test voltages in the circuit, which I admit I am not completely comfortable in doing...

Would I just put the common lead (black) of my multimeter on a GND source and then the Red lead onto the source that I would like to measure?

Just by doing exactly what I have explained above. It seems as though a 11.82 volts does reach each component. If I am doing this incorrectly or if there is a better way to measure voltage could someone please point me in the right direction...

Yes... Unfortunately I am this much of an amateur.

I really appreciate the wisdom and advice!