Re: [korg_mono-poly] Re: Filter Resonance Not Working

2015-12-03 by Florian Anwander

On 03.12.15 20:53 , voltagegrove@yahoo.com [korg_mono-poly] wrote:
> Would I just put the common lead (black) of my multimeter on a GND
> source and then the Red lead onto the source that I would like to measure?
That is correct.


> Just by doing exactly what I have explained above. It seems as though a
> 11.82 volts does reach each component. If I am doing this incorrectly or
> if there is a better way to measure voltage could someone please point
> me in the right direction...
This sounds like your black lead is connected to the -12V supply. Not to 
the Ground. An easy to find ground is the groundwire at the output sockets.

Florian