All, based on the algorithm the bootloader uses to determine the baudrate, as Joel already found out, it is correct that the max baudrate for 12 MHz is 38400 Baud. Will do some additional tests to determine the baudrates for 16 MHz and 24 MHz but we assume that 12 MHz will be the most used crystal as it provides functionality for USB and enables the 60 MHz max. CPU speed as well. Sorry for not providing the appropriate values in the table for the ISP, will update with the next reloease of the Users Manual but that might still take a little while. Robert --- In lpc2000@yahoogroups.com, "Joel Winarske" <joelw@i...> wrote: > > > To get the 48 MHz necessary for the LPC214x USB, you must use a crystal > > of 12.0 MHz, 16.0 MHz, or 24.0 MHz. None of these frequencies are > > mentioned in the manual table 291 that lists the possible ISP baud > > rates with various crystal frequencies. Can you use serial ISP with > > 12/16/24 MHz, and with which baud rates? > > At 12MHz the highest the Phillips Flash utility will connect is 38.4k baud. > I cannot connect running a higher baud. > > Joel >
Message
Re: LPC214x crystal frequencies // ISP max baudrate 38.4 kBaud using 12 MHz
2005-11-17 by philips_apps
Attachments