lpc2100_fan wrote: >Hi Greg, > >one thing that I have seen before that ended up with the same symptoms >your are describing is an IAP call with the wrong frequency. What I am >referring to is you boot up let's say with 14.756 MHz and do some IAP >calls, then you enable the PLL and still call IAP with the same 14.756 >although now it is 59 MHz. > > Is that how you read the manual? I thought that "system clock" was referring to that of the external clocking rate, not that as the PLL clock? Do I have to use the PLL clock rate for this? Regards, TomW -- Tom Walsh - WN3L - Embedded Systems Consultant http://openhardware.net, http://cyberiansoftware.com "Windows? No thanks, I have work to do..." ----------------------------------------------------