--- In lpc2000@yahoogroups.com, Johan Forrer <jbforrer@y...> wrote: > Greetings, > > After being around the block a few times with this > sticky issue, thought I'd pass along my findings. > > Both OcdCommander and OcdLibRemote works with the > Wiggler hardware on the LPC210x, but you'll need to > disconnect nRST connection for the LPC210x target. > > Since nRST behaves differently on my EB40A eval > board(AT91R40008) and I move between these two > platforms, I installed a toggle switch on the Wiggler > box to enable/disable nRST control; Enable nRST for > the Atmel, and disable it for the LPC210x. > > There was some discussion of this issue on Usenet --- > not clear what exactly the issue is, evidently there > are subtle differences. Anyhow, as long as it works > and we can have fun now. OCDCommander works fine for me with nRST connected to the Wiggler. I haven't tried OCDLib Remote with it yet. Leon
Message
Re: OcdLibRemote/OcdCommander and Wiggler on LPC210x
2004-04-15 by leon_heller
Attachments