Actually, I've found just the opposite. I've has to disconnect nRST when working with Atmel ARMs but have had no problem with it being connected when working with the LPC. -Bill Knight R O SoftWare On Thu, 15 Apr 2004 08:50:34 -0000, leon_heller wrote: >--- In lpc2000@yahoogroups.com, Johan Forrer <jbforrer@y...> wrote: >> Greetings, >> >> After being around the block a few times with this >> sticky issue, thought I'd pass along my findings. >> >> Both OcdCommander and OcdLibRemote works with the >> Wiggler hardware on the LPC210x, but you'll need to >> disconnect nRST connection for the LPC210x target. >> >> Since nRST behaves differently on my EB40A eval >> board(AT91R40008) and I move between these two >> platforms, I installed a toggle switch on the Wiggler >> box to enable/disable nRST control; Enable nRST for >> the Atmel, and disable it for the LPC210x. >> >> There was some discussion of this issue on Usenet --- >> not clear what exactly the issue is, evidently there >> are subtle differences. Anyhow, as long as it works >> and we can have fun now. >OCDCommander works fine for me with nRST connected to the Wiggler. I >haven't tried OCDLib Remote with it yet. >Leon
Message
Re: [lpc2000] Re: OcdLibRemote/OcdCommander and Wiggler on LPC210x
2004-04-15 by Bill Knight
Attachments
- No local attachments were found for this message.