Re: [lpc2000] Re: Help: Rowley CrossStudio & Wiggler Problem

2004-04-18 by Robert Adsett

At 04:17 AM 4/19/04 +1000, you wrote:
>It sounds like the way you have it now, your PLL is incorrectly
>programmed, the CCO is not capable of that low frequency, thus
>the capture in range is not possible, _thus_ the PLL doesn't/can't lock.
>The ref manual specifically states that you will yield unreliable operation.

I will add here that the manual is quite correct ;)  I've had the PLL 
programmed incorrectly and the only obvious effect was to make the serial 
baud rate rather odd.  Otherwise the micro seemed to be operating properly 
and at the correct speed.  I suspect the side effect can be even more 
subtle than that.

Robert

" 'Freedom' has no meaning of itself.  There are always restrictions,
be they legal, genetic, or physical.  If you don't believe me, try to
chew a radio signal. "

                         Kelvin Throop, III