--- In lpc2000@yahoogroups.com, "digtalfreak" <digitalfreak@n...> wrote: > > Cut of the reset signal and try again. > At my design it was a problem with the reset. OCDlibremote should work > also with cut of nrst. > > --- In lpc2000@yahoogroups.com, "theeuwke" <theeuwke@y...> wrote: > > > > Hi everybody again. > > > > I'v finally got the Ashling LPC2106 AND my custom 2292 board working. > > But... Only in Crosworks from Rowley??? (And it runs perfectly). I > > configured the LPC2106 according to the Omilex schematics, and the > > LPC2292 to the Omilex 2129 schematics. That seems to work, but if I > > try the ocdremote I get most of the time "Cable disconnect" and some > > times "Not in background". I use Leon's schematic, but use a 74HC244N > > and a BC547C. I tried all speeds. > > > > I am suspecting the Transistor, but it's just an ordinary NPN > > transistor. On the scope I see the nRST pulled up and data on TDI, > > but there is no data getting out. Connecting TRST instead is not the > > solution. > > > > Bart So then there is absolutelly no reset connection?
Message
Re: Wiggler + Crossworks works, ocdremote not?
2004-12-06 by theeuwke
Attachments