Re: [lpc2000] Re: Wiggler + Crossworks works, ocdremote not?

2005-01-16 by Scott Newell

At 12:44 PM 1/16/2005 +0000, leon_heller wrote:
>
>
>Arie de Munck sent me an interface schematic that had pins 8 and 15 
>linked on the DB25 connector. I tried that on my interface and it now 
>works OK with the current OCD Commander software.

Even with this mod, my Olimex is still acting strangely under the recent
OCD Commander.  Anything other than speed 8 gives me the dreaded:
"Error Response from INITIALIZE: 0x03 initialize_target : cable
disconnected  (10 : 03)".

Speed 8 appears to work, but it is horribly slow.  Some of the older
versions seem to work better, in that I can do the initial connect at speed
8, then switch to speed 2 or 3.  But even then, I'm seeing a lot of unknown
opcodes during single stepping, and stepping through a BL doesn't show the
link register updating.


>I've modified my schematic and PCB design and I'll be updating my web 
>page and my files in the Group's Files area.

I think I'll try your circuit next.  This Olimex jtag
'almost-a-wiggler-clone' cable is terribly frustrating.


--