At 12:44 PM 1/16/2005 +0000, leon_heller wrote: > > >Arie de Munck sent me an interface schematic that had pins 8 and 15 >linked on the DB25 connector. I tried that on my interface and it now >works OK with the current OCD Commander software. Even with this mod, my Olimex is still acting strangely under the recent OCD Commander. Anything other than speed 8 gives me the dreaded: "Error Response from INITIALIZE: 0x03 initialize_target : cable disconnected (10 : 03)". Speed 8 appears to work, but it is horribly slow. Some of the older versions seem to work better, in that I can do the initial connect at speed 8, then switch to speed 2 or 3. But even then, I'm seeing a lot of unknown opcodes during single stepping, and stepping through a BL doesn't show the link register updating. >I've modified my schematic and PCB design and I'll be updating my web >page and my files in the Group's Files area. I think I'll try your circuit next. This Olimex jtag 'almost-a-wiggler-clone' cable is terribly frustrating. -- newell
Message
Re: [lpc2000] Re: Wiggler + Crossworks works, ocdremote not?
2005-01-16 by Scott Newell
Attachments
- No local attachments were found for this message.