----- Original Message ----- From: "Scott Newell" <newell@...> To: <lpc2000@yahoogroups.com> Sent: Sunday, January 16, 2005 6:57 PM Subject: Re: [lpc2000] Re: Wiggler + Crossworks works, ocdremote not? > > At 12:44 PM 1/16/2005 +0000, leon_heller wrote: >> >> >>Arie de Munck sent me an interface schematic that had pins 8 and 15 >>linked on the DB25 connector. I tried that on my interface and it now >>works OK with the current OCD Commander software. > > Even with this mod, my Olimex is still acting strangely under the recent > OCD Commander. Anything other than speed 8 gives me the dreaded: > "Error Response from INITIALIZE: 0x03 initialize_target : cable > disconnected (10 : 03)". > > Speed 8 appears to work, but it is horribly slow. Some of the older > versions seem to work better, in that I can do the initial connect at > speed > 8, then switch to speed 2 or 3. But even then, I'm seeing a lot of > unknown > opcodes during single stepping, and stepping through a BL doesn't show the > link register updating. > > >>I've modified my schematic and PCB design and I'll be updating my web >>page and my files in the Group's Files area. > > I think I'll try your circuit next. This Olimex jtag > 'almost-a-wiggler-clone' cable is terribly frustrating. My interface works OK at the max. speed setting (1). My real Wiggler will only manage 3! I've updated the files in jtag.zip. Leon -- No virus found in this outgoing message. Checked by AVG Anti-Virus. Version: 7.0.300 / Virus Database: 265.6.12 - Release Date: 14/01/2005
Message
Re: [lpc2000] Re: Wiggler + Crossworks works, ocdremote not?
2005-01-16 by Leon Heller
Attachments