Yahoo Groups archive

Lpc2000

Index last updated: 2026-04-28 23:31 UTC

Message

Re: [lpc2000] Re: SPI Perph useless for Word data ????

2005-01-17 by Markus Meng

Will this mean that we are not able
to make simple use of SPI-based serial data flash
for file storage and SPI based Ethernet MAC/PHY's
like the one coming up from microchip by simple
connecting these devices to the SPI bus adding
additional dedicated select pins from Port 0
of the LPC210x family.

I agree I don't know of any device that is just
8 Bit. SPI is a serial protocol and as such I should
be able to handle any word-length in a way.

Markus

Robert Adsett schrieb:

>At 12:03 AM 1/17/05 +0000, you wrote:
>
>
>  
>
>>>So do most SPI peripherals.
>>>Surely ... you just read and write multiples of 8 bits.
>>>      
>>>
>>Nope.  Just try it.  May work for some ADCs/DACs but certainly will
>>not work for all of them.  Multiple Writes may work, but I could
>>never get multiple Reads to work.  The interlocking nature of the
>>status flag logic seems to get confused.  Appears to be pretty much
>>limited to handling only 8 bit contiguous data.
>>    
>>
>
>I'm about to actually.  I don't know of any SPI peripheral (other than bare 
>logic gates) that uses single 8 bit values.
>
>You did note the SPI errata?
>
>  
>
>>If they changed this on the other CPU versions to handle 16b words,
>>well I guess that tells you right there that this SPI must only do 8b
>>data.
>>    
>>
>
>Not really.  If that was the case I don't think they would have kept the 
>original.
>
>I'll let you know what I find.
>
>Robert
>
>" 'Freedom' has no meaning of itself.  There are always restrictions,
>be they legal, genetic, or physical.  If you don't believe me, try to
>chew a radio signal. "
>
>                         Kelvin Throop, III
>
>
>
> 
>Yahoo! Groups Links
>
>
>
> 
>
>
>
>
>  
>

-- 
Mit freundlichen Gr\ufffdssen
Markus Meng

********************************************************************
** Meng Engineering        Telefon    056 222 44 10               **
** Markus Meng             Natel      079 230 93 86               **
** Bruggerstr. 21          Telefax    056 222 44 34               **
** CH-5400 Baden           Web        www.meng-engineering.ch     **
********************************************************************