At 04:36 AM 1/25/05 +0000, you wrote:
>Yes, have tried several different computer with different COM ports.
>At school today I have had access to an oscolliscope and found out
>that the philips program is sending out a string of question marks
>trying to get the chip to respond with Synchronized, but the chip just
>sets there. However on the same computer and COM port I can fire up
>HyperTerminal send a single "?" and get the Synchronized response as
>expected. Still at a loss here, can't figure out what would cause this.
Have you tried a different cable? This is the kind of thing I've seen with
intermittent connections (cold solder joint, lead sitting on pad w/o
solder, a broken wire that makes contact as long as the cable sits just
so). Also are you using the appropriate power supply for your level
translator (not running a 5V chip on 3.3V)?
Robert
" 'Freedom' has no meaning of itself. There are always restrictions,
be they legal, genetic, or physical. If you don't believe me, try to
chew a radio signal. "
Kelvin Throop, IIIMessage
Re: [lpc2000] Re: Strange ISP Problem
2005-01-25 by Robert Adsett
Attachments