kenbnny wrote:

> 
> Hello Guys,
> 
> I'm using OCD commander software of Macraigor Systems for connecting 
> to the LPC device using "WIGGLER" Interface. 
> 
> Does anybody know why always I get this message reported.
> "Error Response from INITIALIZE: 0x03 initialize_target : cable 
> disconnected  (10 : 03)"

Are you using a Macraigor Wiggler or a home built one ?
Recently Macraigor added code to their later ocd commander on ocdremote 
software to sense a looped back pin to see if a 'real' wiggler or not.

Suggestions:
* Try an older version of ocd commander (I don't have, but sure someone 
here will. I only have an older version of ocdremote).
* Look back through this list history to see which pins need to be 
looped back on a home grown wiggler to make it look like a macraigor.
* Check your parallel port is in EPP mode (CMOS setup).


-- 
Cheers,
Bruce
-------------------------------------------------------------------
This email and any files transmitted with it are confidential and
intended solely for the use of the individual or entity to whom
they are addressed. If you have received this email in error please
notify the system manager.

     /\\\/\\\/\\\    /   /      Bruce Paterson
    /  \\\ \\\ \\\  /   /    Senior Design Engineer
   /   /\\\/\\\/\\\/   /   8 Anzed Court, Mulgrave, Vic, 3170
  /   /  \\\ \\\ \\\  /  PO Box 4112, Mulgrave, Vic, 3170, Australia
/   /    \\\/\\\ \\\/   Ph: +61 3 8561 4232   Fax: +61 3 9560 9055
       Tele-IP Ltd.      Email: bruce@...    Icq: #32015991