I've used it in both WIGGLER and Raven modes with the LPC. I use an older version of OCBLibRemote with the following command lines: OcdLibRemote.exe -c ARM7 -p 1000 -d WIGGLER -s 4 or OcdLibRemote.exe -c ARM7 -p 1000 -d RAVEN -s 4 The 's' param may be a bit slow but is the setting for the project on which I am currently working. I typically use the RAVEN mode except when using CrossWorks which only supports the WIGGLER mode (they may have RAVEN mode now, not sure). Also, the code for the Chameleon itsself has not been updated from their web site in some time. Regards -Bill Knight R O SoftWare & http://www.theARMPatch.com On Thu, 26 May 2005 12:45:07 +0100, Leon Heller wrote: A long time ago Amontec gave me one of their Chameleon units to try with my LPC210x board. I couldn't get it to work. I thought I'd try it again with the latest software, but still can't get it to work in either Wiggler or Raven mode, even at very low speeds. A genuine Wiggler works fine, of course. Has anyone got the Chameleon to work with the Philips ARM chips? Leon --
Message
Re: [lpc2000] Amontec Chameleon
2005-05-26 by Bill Knight
Attachments