Hi Leon The two units are internal to the equipment (simply 2 internal board connected by flat band) and the two board are never disconnected/connected. There are diodes clamping over and under voltage to the 3V3 / 0V rails (like in most chips to protect inputs). By the way there was a unit which I measured which was getting quite hot (not a port issue) and I found that there was a power supply problem and the LPC2106 was getting 7V8 instead of 3V3. It was getting very hot but otherwise the equipment was still worked fine.....(not to be advised though ;-) ) Regards Mark www.mjbc.ch > > Something might be happening when you are connecting the units together. I'd > be inclined to put something like 3.3 V Transguards (made by AVX) on all the > lines. > > Leon
Message
Re: LPC2106 Ports (sensitivity to destruction?)
2005-08-27 by Mark Butcher
Attachments
- No local attachments were found for this message.